Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 7: 40640, 2017 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-28145525

RESUMO

This work aims to assess the impact of an additional endorectal coil on image quality and cancer detection rate within the same patients. At a single academic medical center, this transversal study included 41 men who underwent T2- and diffusion-weighted imaging at 3 T using surface coils only or in combination with an endorectal coil in the same session. Two blinded readers (A and B) randomly evaluated all image data in separate sessions. Image quality with respect to localization and staging was rated on a five-point scale. Lesions were classified according to their prostate imaging reporting and data system (PIRADS) score version 1. Standard of reference was provided by whole-mount step-section analysis. Mean image quality scores averaged over all localization-related items were significantly higher with additional endorectal coil for both readers (p < 0.001), corresponding staging-related items were only higher for reader B (p < 0.001). With an endorectal coil, the rate of correctly detecting cancer per patient was significantly higher for reader B (p < 0.001) but not for reader A (p = 0.219). The numbers of histologically confirmed tumor lesions were rather similar for both settings. The subjectively rated 3-T image quality was improved with an endorectal coil. In terms of diagnostic performance, the use of an additional endorectal coil was not superior.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/normas , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Humanos , Processamento de Imagem Assistida por Computador , Biópsia Guiada por Imagem , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Estadiamento de Neoplasias , Neoplasias da Próstata/patologia , Sensibilidade e Especificidade
2.
PLoS One ; 11(1): e0147523, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26799970

RESUMO

OBJECTIVE: Chronic recurrent multifocal osteomyelitis/ chronic non-bacterial osteomyelitis (CRMO/ CNO) is a rare auto-inflammatory disease and typically manifests in terms of musculoskeletal pain. Because of a high frequency of musculoskeletal disorders in children/ adolescents, it can be quite challenging to distinguish CRMO/ CNO from nonspecific musculoskeletal pain or from malignancies. The purpose of this study was to evaluate the visibility of CRMO lesions in a whole-body diffusion-weighted imaging (WB-DWI) technique and its potential clinical value to better characterize MR-visible lesions. MATERIAL AND METHODS: Whole-body imaging at 3T was performed in 16 patients (average: 13 years) with confirmed CRMO. The protocol included 2D Short Tau Inversion Recovery (STIR) imaging in coronal and axial orientation as well as diffusion-weighted imaging in axial orientation. Visibility of lesions in DWI and STIR was evaluated by two readers in consensus. The apparent diffusion coefficient (ADC) was measured for every lesion and corresponding reference locations. RESULTS: A total of 33 lesions (on average 2 per patient) visible in STIR and DWI images (b = 800 s/mm2 and ADC maps) were included, predominantly located in the long bones. With a mean value of 1283 mm2/s in lesions, the ADC was significantly higher than in corresponding reference regions (782 mm2/s). By calculating the ratio (lesion to reference), 82% of all lesions showed a relative signal increase of 10% or higher and 76% (25 lesions) showed a signal increase of more than 15%. The median relative signal increase was 69%. CONCLUSION: This study shows that WB-DWI can be reliably performed in children at 3T and predominantly, the ADC values were substantially elevated in CRMO lesions. WB-DWI in conjunction with clinical data is seen as a promising technique to distinguish benign inflammatory processes (in terms of increased ADC values) from particular malignancies.


Assuntos
Imagem de Difusão por Ressonância Magnética , Osteomielite/diagnóstico , Imagem Corporal Total , Adolescente , Criança , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Osteomielite/patologia , Reprodutibilidade dos Testes
3.
PLoS One ; 10(7): e0134370, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26222443

RESUMO

OBJECTIVES: MRI is of great clinical utility for the guidance of special diagnostic and therapeutic interventions. The majority of such procedures are performed iteratively ("in-and-out") in standard, closed-bore MRI systems with control imaging inside the bore and needle adjustments outside the bore. The fundamental limitations of such an approach have led to the development of various assistance techniques, from simple guidance tools to advanced navigation systems. The purpose of this work was to thoroughly assess the targeting accuracy, workflow and usability of a clinical add-on navigation solution on 240 simulated biopsies by different medical operators. METHODS: Navigation relied on a virtual 3D MRI scene with real-time overlay of the optically tracked biopsy needle. Smart reference markers on a freely adjustable arm ensured proper registration. Twenty-four operators - attending (AR) and resident radiologists (RR) as well as medical students (MS) - performed well-controlled biopsies of 10 embedded model targets (mean diameter: 8.5 mm, insertion depths: 17-76 mm). Targeting accuracy, procedure times and 13 Likert scores on system performance were determined (strong agreement: 5.0). RESULTS: Differences in diagnostic success rates (AR: 93%, RR: 88%, MS: 81%) were not significant. In contrast, between-group differences in biopsy times (AR: 4:15, RR: 4:40, MS: 5:06 min:sec) differed significantly (p<0.01). Mean overall rating was 4.2. The average operator would use the system again (4.8) and stated that the outcome justifies the extra effort (4.4). Lowest agreement was reported for the robustness against external perturbations (2.8). CONCLUSIONS: The described combination of optical tracking technology with an automatic MRI registration appears to be sufficiently accurate for instrument guidance in a standard (closed-bore) MRI environment. High targeting accuracy and usability was demonstrated on a relatively large number of procedures and operators. Between groups with different expertise there were significant differences in experimental procedure times but not in the number of successful biopsies.


Assuntos
Biópsia por Agulha/métodos , Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Biópsia por Agulha/instrumentação , Simulação por Computador , Humanos , Biópsia Guiada por Imagem/instrumentação , Imageamento Tridimensional , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Fatores de Tempo , Interface Usuário-Computador
4.
Acta Radiol ; 56(1): 121-8, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24504488

RESUMO

BACKGROUND: Clinical management of prostate cancer increasingly aims to distinguish aggressive types that require immediate and radical treatment from indolent tumors that are candidates for watchful waiting. This requires reliable and reproducible parameters to effectively control potential cancer progression. Magnetic resonance imaging (MRI) may provide a non-invasive means for this purpose. PURPOSE: To assess the value of diffusion-weighted imaging and proton MR spectroscopy for the prediction of prostate cancer (PCa) aggressiveness. MATERIAL AND METHODS: In 39 of 64 consecutive patients who underwent endorectal 3-T MRI prior to radical prostatectomy, prostate specimens were analyzed as whole-mount step sections. Apparent diffusion coefficient (ADC), normalized ADC (nADC: tumor/healthy tissue), choline/citrate (CC), and (choline + creatine)/citrate (CCC) ratios were correlated with Gleason scores (GS) from histopathological results. The power to discriminate low (GS ≤ 6) from higher-risk (GS ≥ 7) tumors was assessed with receiver operating characteristics (area under the curve [AUC]). Resulting threshold values were used by a blinded reader to distinguish between aggressive and indolent tumors. RESULTS: Ninety lesions (1 × GS = 5, 41 × GS = 6, 36 × GS = 7, 12 × GS = 8) were considered. nADC (AUC = 0.90) showed a higher discriminatory power than ADC (AUC = 0.79). AUC for CC and CCC were 0.73 and 0.82, respectively. Using either nADC < 0.46 or CCC > 1.3, as well as both criteria for aggressive PCa, the reader correctly identified aggressive and indolent tumors in 31 (79%), 28 (72%), and 33 of 39 patients (85%), respectively. Predictions of tumor aggressiveness from TRUS-guided biopsies were correct in 27 of 36 patients (75%). CONCLUSION: The combination of a highly sensitive normalized ADC with a highly specific CCC was found to be well suited to prospectively estimate PCa aggressiveness with a similar diagnostic accuracy as biopsy results.


Assuntos
Biomarcadores Tumorais/análise , Colina/análise , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Neoplasias da Próstata/química , Neoplasias da Próstata/diagnóstico , Espectroscopia de Prótons por Ressonância Magnética/métodos , Idoso , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Imagem Molecular/métodos , Invasividade Neoplásica , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
NMR Biomed ; 26(11): 1412-9, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23801556

RESUMO

Signal intensities of T2-weighted magnetic resonance images depend on the local fiber arrangement in hyaline cartilage. The aims of this study were to determine whether angle-sensitive MRI at 7 T can be used to quantify the cartilage ultrastructure of the knee in vivo and to assess potential differences with age. Ten younger (21-30) and ten older (55-76 years old) healthy volunteers were imaged with a T2-weighted spin-echo sequence in a 7 T whole-body MRI. A "fascicle" model was assumed to describe the depth-dependent fiber arrangement of cartilage. The R/T boundary positions between radial and transitional zones were assessed from intensity profiles in small regions of interest in the femur and tibia, and normalized to cartilage thickness using logistic curve fits. The quality of our highly resolved (0.3 × 0.3 × 1.0 mm(3)) MR cartilage images were high enough for quantitative analysis (goodness of fit R(2) = 0.91 ± 0.09). Between younger and older subjects, normalized positions of the R/T boundary, with value 0 at the bone-cartilage interface and 1 at the cartilage surface, were significantly (p < 0.05) different in femoral (0.51 ± 0.12 versus 0.41 ± 0.10), but not in tibial cartilage (0.65 ± 0.11 versus 0.57 ± 0.09, p = 0.119). Within both age groups, differences between femoral and tibial R/T boundaries were significant. Using a fascicle model and angle-sensitive MRI, the depth-dependent anisotropic fiber arrangement of knee cartilage could be assessed in vivo from a single 7 T MR image. The derived quantitative parameter, thickness of the radial zone, may serve as an indicator of the structural integrity of cartilage. This method may potentially be suitable to detect and monitor early osteoarthritis because the progressive disintegration of the anisotropic network is also indicative of arthritic changes in cartilage.


Assuntos
Cartilagem Articular/ultraestrutura , Joelho/anatomia & histologia , Imageamento por Ressonância Magnética , Adulto , Idoso , Feminino , Fêmur/anatomia & histologia , Humanos , Masculino , Pessoa de Meia-Idade , Tíbia/anatomia & histologia , Adulto Jovem
6.
J Magn Reson Imaging ; 37(5): 1144-50, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23124651

RESUMO

PURPOSE: To present software for supervised automatic quantification of visceral and subcutaneous adipose tissue (VAT, SAT) and evaluates its performance in terms of reliability, interobserver variation, and processing time, since fully automatic segmentation of fat-fraction magnetic resonance imaging (MRI) is fast but susceptible to anatomical variations and artifacts, particularly for advanced stages of obesity. MATERIALS AND METHODS: Twenty morbidly obese patients (average BMI 44 kg/m(2) ) underwent 1.5-T MRI using a double-echo gradient-echo sequence. Fully automatic analysis (FAA) required no user interaction, while supervised automatic analysis (SAA) involved review and manual correction of the FAA results by two observers. Standard of reference was provided by manual segmentation analysis (MSA). RESULTS: Average processing times per patient were 6, 6+4, and 21 minutes for FAA, SAA, and MSA (P < 0.001), respectively. For VAT/SAT assessment, Pearson correlation coefficients, mean (bias), and standard deviations of the differences were R = 0.950, +0.003, and 0.043 between FAA and MSA and R = 0.981, +0.009, and 0.027 between SAA and MSA. Interobserver variation and intraclass correlation were 3.1% and 0.996 for SAA, and 6.6% and 0.986 for MSA, respectively. CONCLUSION: The presented supervised automatic approach provides a reliable option for MRI-based fat quantification in morbidly obese patients and was much faster than manual analysis.


Assuntos
Gordura Abdominal/patologia , Adiposidade , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Obesidade Mórbida/patologia , Reconhecimento Automatizado de Padrão/métodos , Software , Adolescente , Adulto , Algoritmos , Feminino , Humanos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
7.
J Magn Reson Imaging ; 37(6): 1480-5, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23055397

RESUMO

PURPOSE: To present a novel method for MR elastography (MRE) of the prostate at 3 Tesla using a modified endorectal imaging coil. MATERIALS AND METHODS: A commercial endorectal coil was modified to dynamically generate mechanical stress (contraction and dilation) in a prostate phantom with embedded phantom "lesions" (6 mm diameter) and in a porcine model. Resulting tissue displacements were measured with a motion-sensitive EPI sequence at actuation frequencies of 50-200 Hz. Maps of shear modulus G were calculated from the measured phase-difference shear-wave patterns. RESULTS: In the G maps of the phantom, "lesions" were easily discernible against the background. The average G values of regions of interest placed in the "lesion" (8.2 ± 1.9 kPa) were much higher than those in the background (3.6 ± 1.4 kPa) but systematically lower than values reported by the vendor (13.0 ± 1.0 and 6.7 ± 0.7 kPa, respectively). In the porcine model, shear waves could be generated and measured shear moduli were substantially different for muscle (7.1 ± 2.0 kPa), prostate (3.0 ± 1.4 kPa), and bulbourethral gland (5.6 ± 1.9 kPa). CONCLUSION: An endorectal MRE concept is technically feasible. The presented technique will allow for simultaneous MRE and MRI acquisitions using a commercial base device with minor, MR-conditional modifications. The diagnostic value needs to be determined in further trials.


Assuntos
Técnicas de Imagem por Elasticidade/instrumentação , Aumento da Imagem/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Magnetismo/instrumentação , Próstata/patologia , Próstata/fisiologia , Transdutores , Módulo de Elasticidade/fisiologia , Humanos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Imagens de Fantasmas , Reto/patologia , Reto/fisiologia , Estresse Mecânico
8.
Eur Radiol ; 22(8): 1820-8, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22527373

RESUMO

OBJECTIVES: To evaluate the influence of the choice of b values on the diagnostic value of the apparent diffusion coefficient (ADC) for detection and grading of prostate cancer (PCa). METHODS: Forty-one patients with biopsy-proven PCa underwent endorectal 3-T MRI before prostatectomy. Different combinations of b values (0-800 s/mm(2)) were used to calculate four representative ADC maps. Mean ADCs of tumours and non-malignant tissue were determined. Tumour appearance on different ADC maps was rated by three radiologists as good, fair or poor by assigning a visual score (VS) of 2, 1 or 0, respectively. Differences in the ADC values with the choice of b values were analysed using one-way ANOVA. RESULTS: Choice of b values had a highly (P < 0.001) significant influence on the absolute ADC in each tissue. Maps using b = [50, 800] and [0, 800] were rated best (VS= 1.6 ± 0.3) and second best (1.1 ± 0.3, P < 0.001), respectively. For low-grade carcinomas (Gleason score ≤ 6, 13/41 patients), only the former choice received scores better than fair (VS = 1.4 ± 0.3). Mean tumour ADCs showed significant negative correlation (Spearman's ρ -0.38 to -0.46, P < 0.05) with Gleason score. CONCLUSIONS: Absolute ADC values strongly depend on the choice of b values and therefore should be used with caution for diagnostic purposes. A minimum b value greater than zero is recommended for ADC calculation to improve the visual assessment of PCa in ADC maps. KEY POINTS: • Absolute ADC values are highly dependent on the choice of b values. • Absolute ADC thresholds should be used carefully to predict tumour aggressiveness. • Subjective ratings of ADC maps involving b = 0 s/mm ( 2 ) are poor to fair. • Minimum b value greater than 0 s/mm ( 2 ) is recommended for ADC calculation.


Assuntos
Imageamento por Ressonância Magnética/métodos , Oncologia/métodos , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/patologia , Idoso , Diagnóstico por Imagem/métodos , Diagnóstico por Imagem/normas , Difusão , Imagem Ecoplanar/métodos , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Variações Dependentes do Observador , Antígeno Prostático Específico/biossíntese , Prostatectomia/métodos , Estudos Retrospectivos
9.
Magn Reson Imaging ; 30(3): 371-81, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22244541

RESUMO

PURPOSE: To determine whether a greatly reduced spatial resolution of fully reconstructed projection MR images can be used for the simultaneous 3D localization of multiple MR-visible markers and to assess the feasibility of a subsecond position tracking for clinical purposes. MATERIALS AND METHODS: Miniature, inductively coupled RF coils were imaged in three orthogonal planes with a balanced steady-state free precession (SSFP) sequence and automatically localized using a two-dimensional template fitting and a subsequent three-dimensional (3D) matching of the coordinates. Precision, accuracy, speed and robustness of 3D localization were assessed for decreasing in-plane resolutions (0.6-4.7 mm). The feasibility of marker tracking was evaluated at the lowest resolution by following a robotically driven needle on a complex 3D trajectory. RESULTS: Average 3D precision and accuracy, sensitivity and specificity of localization ranged between 0.1 and 0.4 mm, 0.5 and 1.0 mm, 100% and 95%, and 100% and 96%, respectively. At the lowest resolution, imaging and localization took ≈350 ms and provided an accuracy of ≈1.0 mm. In the tracking experiment, the needle was clearly depicted on the oblique scan planes defined by the markers. CONCLUSION: Image-based marker localization at a greatly reduced spatial resolution is considered a feasible approach to monitor reference points or rigid instruments at subsecond update rates.


Assuntos
Marcadores Fiduciais , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Desenho de Equipamento , Estudos de Viabilidade , Humanos , Imageamento Tridimensional/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Sensibilidade e Especificidade
10.
Med Phys ; 38(11): 6327-35, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22047397

RESUMO

PURPOSE: MR-visible markers have already been used for various purposes such as image registration, motion detection, and device tracking. Inductively coupled RF (ICRF) coils, in particular, provide a high contrast and do not require connecting wires to the scanner, which makes their application highly flexible and safe. This work aims to thoroughly characterize the MR signals of such ICRF markers under various conditions with a special emphasis on fully automatic detection. METHODS: The small markers consisted of a solenoid coil that was wound around a glass tube containing the MR signal source and tuned to the resonance frequency of a 1.5 T MRI. Marker imaging was performed with a spoiled gradient echo sequence (FLASH) and a balanced steady-state free precession (SSFP) sequence (TrueFISP) in three standard projections. The signal intensities of the markers were recorded for both pulse sequences, three source materials (tap water, distilled water, and contrast agent solution), different flip angles and coil alignments with respect to the B(0) direction as well as for different marker positions in the entire imaging volume (field of view, FOV). Heating of the ICRF coils was measured during 10-min RF expositions to three conventional pulse sequences. Clinical utility of the markers was assessed from their performance in computer-aided detection and in defining double oblique scan planes. RESULTS: For almost the entire FOV (±215 mm) and an estimated 82% of all possible RF coil alignments with respect to B(0), the ICRF markers generated clearly visible MR signals and could be reliably localized over a large range of flip angles, in particular with the TrueFISP sequence (0.3°-4.0°). Generally, TrueFISP provided a higher marker contrast than FLASH. RF exposition caused a moderate heating (≤5 °C) of the ICRF coils only. CONCLUSIONS: Small ICRF coils, imaged at low flip angles with a balanced SSFP sequence showed an excellent performance under a variety of experimental conditions and therefore make for a reliable, compact, flexible, and relatively safe marker for clinical use.


Assuntos
Marcadores Fiduciais , Imageamento por Ressonância Magnética/normas , Miniaturização/instrumentação , Ondas de Rádio , Estudos de Viabilidade , Temperatura Alta , Humanos
11.
Magn Reson Med ; 64(3): 922-8, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20806383

RESUMO

MRI is of great clinical utility for the guidance of various diagnostic and therapeutic procedures. In a standard closed-bore scanner, the simplest approach is to manipulate the instrument outside the bore and move the patient into the bore for reference and control imaging only. Without navigational assistance, however, such an approach can be difficult, inaccurate, and time consuming. Therefore, an add-on navigation solution is described that addresses these limitations. Patient registration is established by an automatic, robust, and fast (<30 sec) localization of table-mounted MR reference markers and the instrument is tracked optically. Good hand-eye coordination is provided by following the virtual instrument on MR images that are reconstructed in real time from the reference data. Needle displacements of 2.2 +/- 0.6 mm and 3.9 +/- 2.4 mm were determined in a phantom (P < 0.05), depending on whether the reference markers were placed at smaller (98-139 mm) or larger (147-188 mm) distances from the isocenter. Clinical functionality of the navigation concept is demonstrated by a double oblique, subscapular hook-wire insertion in a patient with a body mass index of 30.1 kg/m(2). Ease of use, compactness, and flexibility of this technique suggest that it can be used for many other procedures in different body regions. More patient cases are needed to evaluate clinical performance and workflow.


Assuntos
Imagem por Ressonância Magnética Intervencionista/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Magnetismo/instrumentação , Cirurgia Assistida por Computador/instrumentação , Transdutores , Elasticidade , Desenho de Equipamento , Análise de Falha de Equipamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...